HEPA filters used in hospital operating room
HEPA filters used in hospital operating room

Temperature operation between the regulator is very important, there should be air-conditioning equipment. The air conditioner should be located in the upper roof, room temperature maintained at 24 ~ 26oC, relative humidity of about 50% is appropriate.General surgery between 35 ~ 45m2, special room about 60m2, suitable for cardiopulmonary bypass surgery, organ transplants, etc.; minor surgery room area at 20 ~ 30m2.
Mid-20th century, high efficiency air filters, HEPA filter, air filter - HEPA filter in the operating room in a hospital ward began to centralize applications, operating room also entered a third era: centralized operating room (Central Type OPR). In 1955, the University of Tokyo Department of Surgery centralized center officially opened, opened a Japanese centralized theater curtain; 1963, central supply-type operating room layout was born in the United States; 1966, the world's first inter-laminar flow clean Operating room set up in the United States Barton Memorial Hospital; 1969, the British Ministry of Health recommended operating room layout, is the prototype of dirt recovery type is widely used today.
Operating room air pressure according to the different regions (such as
the operating room, sterile preparation room, scrub room, a clean room
anesthesia and the surrounding area, etc.) the cleanliness of the different
requirements and different. Different levels of laminar flow operating room air cleanliness standards
of its different HEPA filter, HEPA filter, air filter - HEPA filter used in
hospital operating rooms, such as the U.S. Federal Standard 1000 cubic feet of
air per The number of dust particles ≥ 0.5μm, ≤ 1000 SVs or per liter of air ≤
35 stars. 10000 standard laminar flow operating room for each cubic foot of air in
the number of dust particles ≥ 0.5μm's, ≤ 10000 SVs or per liter of air ≤ 350
stars. The main purpose is to exclude the operating room ventilation exhaust
within each workplace; ensure that all workplaces necessary amount of fresh air;
remove dust and microorganisms; maintain indoor necessary
positive. Able to
meet the requirements of the operating room ventilation mechanical ventilation
has the following two. Mechanical ventilation with mechanical ventilation and formula: This
ventilation can control the number of ventilators, ventilation and indoor
pressure ventilation is better. Mechanical ventilation and natural ventilation and use, ventilation and
air changes this subject to certain restrictions ventilation, ventilation as
effective as the former. Mainly clean operating room level of dust particles in the air, and the
number of biological particles to distinguish. 。 Currently,
the most commonly used is the NASA classification. Purify air purification technology by positive air flow control to achieve
sterile cleanliness purposes.
Health industry is a very large and special industry, its air cleanliness
requirements are high. Typically, the
minimum requirements for hospital use efficiency of the air pre-filter and a 30%
efficiency of the filter is 90% of the final combination of
filtration. Under normal circumstances does not require HEPA
filters, but in exceptional circumstances, such as isolation rooms, specific
tests and care area will need to HEPA filters.
Many HVAC systems to use 100 percent
of the hospital's outdoor air, which is for the patient to prevent
cross-infection by microorganisms suspended HVAC system is a good
strategy. But 100% outdoor
air does not eliminate microbial growth and its adverse effects on the
environment of care in the air filtration media. So now many hospitals are still in dire
need of advanced HVAC systems.
Cleanroom
health system was first used in the operating room. It just started to get widely used in orthopedic surgery, orthopedic
surgery since a long time, easy to cause infection. The desirable level of control is to use clean air reaches the operating
table 100 near. Generally recommended to use the top of the
HEPA filtration system that can cover at least 3 m × 3 m area, which included
the operating table and the people.
Depending aspirated mode, the purification techniques can be divided into
two turbulent and laminar flow systems. (1) turbulence system (Multi-Directional Manner): turbulent systems and
high efficiency filter outlet located in the ceiling, back or sides of the
outlet located at the lower side of the wall, filters and air treatment is
relatively simple, easy expansion low cost, but fewer ventilation, usually 10 to
50 times / h, prone vortex particle pollution indoors may be suspended
circulating vortex area, forming pollution airflow, reduce indoor purification
degree. NASA standard applies only to 1000 000 10 000 clean room. (2) laminar flow system (Laminal Flow System); laminar flow and velocity
distribution systems utilize proper airflow, high efficiency air filters, HEPA
filter, air filter - HEPA filter used in hospital operating rooms will particles
of dust through the return air to bring out the operating room, no eddy, there
is no floating dust, with increasing degree of purification and improved
ventilation times for NASA standard 100 operating room. However, the
filter seal breakage rate is relatively large, and higher cost.
Other areas of cleanroom applications have access to the delivery room, nursery, burn room, cardiac care unit, etc.. One of the latest developments is the application of dental surgery cleanroom, which reduces the risk of long-term medical staff during surgery is infection.With the development of high technology, more purification equipment will also apply to the hospital being.